Surgex Rack Mount Surge Eliminator and Power Conditioner, 20A/120V, 1U Promotion Saisonnière

Promo !

Surgex Rack Mount Surge Eliminator and Power Conditioner, 20A/120V, 1U Promotion Saisonnière

Le prix initial était : 1 145,70 €.Le prix actuel est : 458,28 €.

UGS : SK0016227 Catégorie : Étiquette :

Description

Featuring Advanced Series Mode surge elimination technology, the SurgeX Rack Mount product line safeguards sensitive equipment that relies on audio and video performance. Unlike common protection solutions, this patented technology is non-sacrificial and eliminates surge energy up to 6,000 volts without producing harmful side effects such as ground contamination or common-mode disturbances that can degrade the performance of AV systems.
With SurgeX rack mount solutions your connected equipment will be protected from destructive spikes, surges, and inductive transients that can cause disruptions and catastrophic damage.
Features:
Advances Series Mode surge elimination technology
Catastrophic over/under Voltage Shutdown Protection
ICE Inrush Current Elimination
EMI/RFI filter
Thermal circuit breaker overload protection
Improves audio and video performance
Non-sacrificial components
A-1-1 Certified
Specifications for SX-1120-RT:
Load Rating: 20 @ 120 volts
Power Requirement (no load): 15 watts
Surge Let-Through Voltage (6000-volt surge): 0 Volts
UL 1449 Adjunct Classification Test Results: 1000 surges, 6000 volts, 3000 amps, B3 pulse
Measured suppressed voltage: 170 volts, no failures
Federal Guidelines: Grade A, Class 1, Mode 1 (CID A-A-55818)
EMI/RFI Filter, Normal Mode (50-ohm load):
40 dB @ 100 kHz; 50 dB @ 300 kHz;
50 dB @ 3 MHz; 50 dB @ 30 MHz
EMI/RFI Filter, Common Mode (50-ohm load):
18 dB @ 300 kHz; 30 dB @ 1 MHz;
50 dB @ 5 MHz; 50 dB @ 20 MH
Maximum Applied Surge Voltage: 6000 volts*
Maximum Applied Surge Current: Unlimited, due to current limiting*
Maximum Applied Surge Energy: Unlimited, due to current limiting*
Endurance (C62.41-1991 Category B3 pulses): 1 kV> 500,000; 3 kV> 10,000; 6 kV> 1000
Undervoltage Shutdown: 90 volts (resume at 100 v)
Overvoltage Shutdown: 145 volts (resume at 135 v)
Maximum Load Inrush Current during Power-up: 1000 Joules
Remote Turn-on Applied Voltage Range: 5 to 30 volts DC
Contact Closure: 1.5 mA
5 V DC Applied Voltage: 0.1 mA;
12 V DC Applied Voltage: 1.5 mA
24 V DC Applied Voltage: 5.0 mA
Auxiliary Relay Contact Rating: 30 Volts at 1 Amp
LED Output: 12 volts DC, maximum 20 mA (resistor required)
Dimensions: 1.75 H x 19 W x 10.5 D (4.5 x 48.3 x 26.7 cm)
Weight: 11 lbs (5 kg)
Temperature Range: 5 to 35 degrees C
Humidity Range: 5% to 95% R.H., non-condensing
Agency Listings: ETL and cETL certified to (UL 1449; CSA C22.2 No.8-M1986, R2000)